Artificial Saliva for Dental-Implant Tests According to ISO 14801
Dental implant research and testing require precise and reliable tools to ensure accurate results. One such indispensable tool in scientific research is Artificial Saliva, specifically formulated for dental-implant tests following the ISO 14801 standard. This blog delves into the significance, composition, benefits, and various applications of using Artificial Saliva for in vitro testing and research purposes. Additionally, we’ll address common questions to provide a comprehensive understanding of this product.
What is Artificial Saliva for Dental Implant Tests?
Artificial Saliva, also known as Simulated saliva, is a scientifically developed solution designed to mimic the mineral composition and properties of natural saliva. Its primary purpose is for scientific research and in vitro applications. This includes:
- Dental implant studies
- Medical device and equipment testing
- Fatigue testing under ISO 14801 standards
The solution’s carefully balanced pH of 6.8 replicates the natural environment of the human oral cavity, making it indispensable for accurate product testing and research. However, it is important to note that this product is intended solely for laboratory use and not for medical procedures or in vivo applications.
Explore this premium quality Artificial Saliva here: https://biochemazone.com/product/artificial-saliva-iso-14801-2016/
Key Features
1. ISO 14801 Compliance
Simulated saliva adheres to the ISO 14801-2016 standard, ensuring its reliability and accuracy in dental implant fatigue testing. Its formulation is specifically designed to replicate the mineral composition of natural saliva, enabling consistent results in a controlled environment.
2. Customizable Formulations
Researchers often have unique requirements for their experiments. Simulated saliva offers customizable options, including different pH levels and stabilized versions, tailored to meet specific research needs.
3. Available Pack Sizes
To cater to various research scales, It is available in multiple pack sizes:
- 100 mL
- 200 mL
- 500 mL
- 1000 mL
This versatility ensures that researchers can choose the most suitable quantity for their experiments, reducing waste and optimizing costs.
4. Convenient Shelf Life Options
It is available in stabilized and non-stabilized versions, with varying shelf lives to suit different storage and usage requirements:
- Not Stabilized Version: Valid for up to 3 months
- Stabilized Version: Valid for up to 6 months when stored at 2-8℃, and up to 1 year when frozen at -20℃
5. Ready-to-Use Formulation
The pre-prepared solution with a pH of 6.8 eliminates the need for additional preparation, saving valuable time and ensuring consistency across multiple experiments.
Applications of Simulated saliva in Research
It plays a crucial role in various research and testing applications, including:
1. Dental Implant Testing
The solution provides a simulated oral environment for evaluating the performance, durability, and biocompatibility of dental implants. It is particularly useful for fatigue testing, which assesses an implant’s ability to withstand repetitive stress.
2. Medical Device and Equipment Testing
Devices and equipment designed for use in the oral cavity must undergo rigorous testing to ensure safety and effectiveness. It creates a realistic testing environment, allowing researchers to evaluate these products under conditions that closely mimic actual usage.
3. Fatigue Testing
Fatigue testing determines how materials and products perform under prolonged stress. The formulation’s similarity to natural saliva makes it ideal for testing dental and medical devices that must endure continuous or repetitive use.
4. Corrosion Studies
Metals and other materials used in dental implants are susceptible to corrosion in the oral environment. It enables researchers to study the corrosion resistance of various materials, ensuring the long-term safety and efficacy of dental products.
5. Biocompatibility Studies
Biocompatibility testing is essential for evaluating how materials interact with biological systems. It provides a controlled medium for studying the compatibility of dental and medical devices with oral tissues.
Composition and Properties
Simulated saliva is formulated to replicate the mineral composition of natural saliva, ensuring accurate and reliable results in research settings. Its key properties include:
- pH Level: 6.8, closely mimicking the natural pH of human saliva
- Mineral Composition: Simulates the ionic balance and chemical properties of real saliva
- Stabilization Options: Available in stabilized and non-stabilized versions to suit different research needs
These characteristics make Artificial Saliva a highly effective solution for in vitro testing.
Storage and Transportation Guidelines
Proper storage and transportation are critical for maintaining the integrity of Artificial Saliva. Below are the recommended guidelines:
Transportation
- Transport the solution at room temperature to ensure stability during transit.
Storage
- Not Stabilized Version: Store at 2-8℃ for up to 3 months.
- Stabilized Version: Store at 2-8℃ for up to 6 months or freeze at -20℃ for a shelf life of up to 1 year.
Adhering to these guidelines ensures the solution retains its properties for reliable and consistent results.
Benefits of Using Artificial Saliva
Artificial Saliva offers several advantages for researchers and product developers:
1. Enhanced Accuracy
The solution’s precise formulation ensures accurate simulation of the oral environment, leading to reliable and reproducible test results.
2. Cost-Effective
Despite its premium quality, Artificial Saliva is available at an affordable price, making it accessible to a wide range of researchers and institutions.
3. Time-Saving
The ready-to-use formulation eliminates the need for time-consuming preparation, allowing researchers to focus on their experiments.
4. Versatility
With customizable options and multiple pack sizes, Artificial Saliva can be tailored to meet the unique needs of different research projects.
How to Order Artificial Saliva
If you are looking for a reliable and high-quality Artificial Saliva solution for your research, visit Biochemazone™. This product offers unmatched quality and affordability, ensuring optimal results for your scientific studies.
FAQs About Artificial Saliva for ISO 14801 Tests
1. What is Artificial Saliva used for?
Artificial Saliva is used for scientific research, particularly for dental implant testing, medical device analysis, and fatigue testing under ISO 14801 standards.
2. Is Artificial Saliva safe for human consumption?
No, Artificial Saliva is intended exclusively for in vitro use and is not safe for in vivo applications or human consumption.
3. How should Artificial Saliva be stored?
The solution should be stored at 2-8℃ for short-term use. For long-term storage, stabilized versions can be frozen at -20℃ for up to 1 year.
4. Can the pH of Artificial Saliva be customized?
Yes, custom pH levels and stabilized versions are available upon request to meet specific research requirements.
5. What are the available pack sizes?
Artificial Saliva is available in 100 mL, 200 mL, 500 mL, and 1000 mL pack sizes.
6. Where can I buy Artificial Saliva?
You can purchase high-quality Artificial Saliva from Biochemazone™, a trusted provider of scientific solutions.
Artificial Saliva is an essential tool for dental and medical research, offering unparalleled accuracy, reliability, and versatility. Ensure the success of your experiments by choosing a product that meets the highest standards of quality and performance.